DIP Switches and Jumper Definitions
DIP Switchbank A Key
A1 ............... Test Mode (normally Off)
A2 ............... In “ON” position, add one high-speed pump (or blower) with Heater
A3 ............... In “ON” position, add two high-speed pumps (or 1 HS Pump and Blower) with Heater
A4 ............... In “ON” position, add four high-speed pumps (or 3 HS Pumps and Blower) with Heater
A10 ............... When switched ON when spa is on, system will enter the Edit Menu for Configuration Settings
Do not start spa with A10 turned on or CFE* error will occur
A11 ............... In “ON” position, enables Special Amperage Rule, see "SA" in Software Configuration section for functionality with your system
............... In “OFF” position, disables Special Amperage Rule
A12 ............... Persistent memory reset (used when spa is powering up) See "Persistent Memory and Powering Up" page
A2, A3, and A4 work in combination to determine the number of high-speed devices and blowers that can run before the heat is disabled. i.e.
A2 and A3 in the ON position and A4 in the OFF position will allow the heater to operate with up to 3 high-speed pumps (or two HS Pumps and
Blower) running at the same time. Heat is disabled when the fourth high-speed pump or blower is turned on.
Note: A2/A3/A4 all off = No heat with any high-speed pump or blower.
*CFE errors are illegal configurations such as a pump and a blower set to run on the same output. The configuration must be corrected before
the spa will operate.
Assignable DIP Switch Key
A5 .............
In “ON” position, Time displayed in 24-hour style (military/European format)
..............In “OFF” position, Time displayed in 12-hour style
A6 and A7
........
See Table 1 for Circ Pump Behavior settings
A8 .............See Table 2 for Spa Light Behavior settings
A9 .............
In “ON” position, Spa Light mode is On/Off
..............In “OFF” position, Spa Light mode is Off/High/Med/Low
B1 .............N/A, must be OFF
B2
..............
See Table 2 for Fiber-Optic Behavior settings
B3 .............
In “ON” position, Option enabled
..............In “OFF” position, Option disabled
B4 .............
In “ON” position, Ozone runs in Filter and Cleanup cycles only
..............In “OFF” position, Ozone runs with Heater Pump
B5 .............
In “ON” position, 1-hour Ozone suppress enabled
..............In “OFF” position, Ozone suppress disabled
B6-B12 ..... Not Assigned
Table 1 Circ Pump
A6 A7 Behavior
OFF OFF No Circ Pump
OFF ON 24-hr Circ Pump
ON OFF 24-hr w-3˚F
ON ON Like P1-low
WARNING:
sSetting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
sRefer to Switchbank illustration in this hot sheet for correct settings for this system.
sContact Balboa if you require additional configuration pages added to this hot sheet.
Jumpers Key
J91 .........Jumper on 1 Pin only enables Real Time Clock function, for use with time capable panels.
Jumper on Pins 1 and 2 will disable RTC function, for use with non-time capable panels.
Table 2 A8 OFF A8 ON
B2 OFF No separately-controlled fiber light; spa light enabled on both SpaLight and EitherLight buttons; fiber
light (not wheel) comes on with spa light (at any intensity)
B2 ON
No separately-controlled fiber light; fiber light
enabled on both FiberLight and EitherLight
buttons; spa light comes on with fiber light
Spa light and fiber light each separately controlled;
fiber light enabled on both FiberLight and EitherLight
buttons; spa light enabled on SpaLight buttons only